The HZ-3007C salt spray test chamber evaluates the corrosion resistance of coated, electroplated, anodized, inorganic-film, organic-film and rust-preventive-oil treated products.
Technical specifications:
1. Chamber dimensions: 60 × 45 × 40 cm; external dimensions: 107 × 60 × 118 cm.
2. Chamber temperature: 35 ±1°C or 50 ±1°C.
3. Saturator temperature: 47 ±1°C or 63 ±1°C.
4. Salt-solution temperature: 35 ±1°C or 50 ±1°C.
5. Chamber capacity: 108 L; solution tank: 15 L.
6. Spray collection: 1.0–2.0 ml/80 cm²/h, averaged over at least 16 hours.
7. Relative humidity: at least 85%.
8. pH ranges: 6.5–7.2 or 3.0–3.2.
9. Programmable continuous or intermittent spray.
10. Power: single-phase AC 220 V, 10 A.